Pressure
Transmitter
|
|
|
Labom
Intelligent Pressure Transmitter with Microprocessor PASCAL Ci - Ci 1000
and Ci 2000 Series
Design Features
| 1. |
Microprocessor-controlled
2-wire pressure transmitter, self monitoring. |
| 2. |
Text-oriented
operating control via graphic display with language module. |
| 3. |
Measuring
range extension 1:20. |
| 4. |
Measuring
ranges 100 mbar up to 400 bar. |
| 5. |
Signal output
4..20 mA, 2-wire. |
| 6. |
Case and wetted
parts of stainless steel, protection type IP 65 or 67. |
| 7. |
Ex-protection,
EEx ia/ib. |
| 8. |
EMC test as
per valid EC guidelines. |
Pascal
Ci Data Sheet
PASCAL
Functional Schematic Diagram
|
 |
Labom
Compact Pressure Transmitter - CB 6010 and CB 6020 Series
Design Features
| 1. |
Measuring
ranges 0...1 bar to 0...160 bar rel./abs. |
| 2. |
Measuring
system piezoresistive, vacuum tight and overload protected. |
| 3. |
Signal output
4...20 mA, 2-wire circuitry. |
| 4. |
Wetted parts
of stainless steel; completely welded. |
| 5. |
Stainless
steel housing, protection type IP 65, optional IP 67. |
| 6. |
Process temperature
up to 140°C. |
| 7. |
EMC test per
valid EC guidelines. |
Data
Sheet
|
 |
Labom
Compact Pressure Transmitter with Flush Mounted Diaphragm - CE 6110 and
CE 6120 Series
Design Features
| 1. |
Measuring
ranges 0...100 mbar to 0...60 bar. |
| 2. |
Measuring
system piezoresistive, vacuum tight and overload protected. |
| 3. |
Signal output
4...20 mA, 2-wire circuitry. |
| 4. |
Wetted parts
of stainless steel; completely welded. |
| 5. |
Flush mounted
diaphragm. |
| 6. |
Process temperature
up to 140°C. |
| 7. |
EMC test per
valid EC guidelines. |
Data
Sheet
|
 |
Labom
Compact Pressure Transmitter with Integrated Diaphragm Seal - CC 6000 Series
Design Features
| 1. |
Measuring
ranges: 0...160 mbar to 0...400 bar rel; 0...1 bar to 10 bar abs. |
| 2. |
Suitable for
all diaphragm seal designs. |
| 3. |
Measuring
system piezoresistive, vacuum tight and overload protected. |
| 4. |
signal output
4...20mA, 2-wire circuitry; 0...20mA, 3-wire circuitry, optional. |
| 5. |
Wetted parts
of stainless steel; completely welded. |
| 6. |
Completely
encapsulated electronics. |
| 7. |
Process temperature
up to 140°C, standard; optional 250°C. |
| 8. |
Ex-protection
EEx ib IIC T6 per ATEX 100a. |
| 9. |
EMC test per
valid EC guidelines. |
Data
Sheet
|
 |
Labom
Pressure Transmitter Compact - Robust for Hazardous Areas - CE 8011 Series
Design Features
| 1. |
Measuring
ranges 0...3 psi to 0...2000 psi or 0...200 mbar to 0...160 bar. |
| 2. |
Vacuum tight
and highly overload protected. |
| 3. |
Signal output
4...20 mA, 2-wire circuitry. |
| 4. |
Process connection
:
- Connection
according to DIN 19213.
- Flange
per ANSI.
- Threaded
connection with adapter.
|
| 5. |
Wetted parts;
stainless steel SS 316L, Tabtalum/Hastelloy C4. |
| 6. |
Fully welded
design. |
| 7. |
Fully encapsulated
electronics unit. |
| 8. |
Ex-approval:
- Explosion proofing Europe CENELEC:
ATEX 100, EEx ib IIC T4.
- Explosion proofing Europe CENELEC:
ATEX 100, EEx d IIC T4.
- Explosion proofing USA Factory
Mutual (FM).
- Explosion proofing Canada CSA.
|
Data
Sheet
|
 |
Labom
Pressure Transmitter For Gasses - CF Series
Design Features
| 1. |
Measuring
ranges 0...0.16 bar up to 0...10 bar rel. |
| 2. |
Piezoresistive
sensor element. |
| 3. |
High degree
of accuracy up to 0.1% f.s. |
| 4. |
Stainless
steel housing as standard or field housing. |
| 5. |
Signal output:
various load independent standard signals. |
| 6. |
Power supply:
24 V DC, 2- and 3-wire circuitry. |
| 7. |
Explosion
proof: EEx ia/ib. |
| 8. |
Electromagnetic
Compatibility (EMC) Test per IEC 801. |
|
 |
Labom
Pressure Transmitter - Measuring Principle Piezoresistive - For Diaphragm
Seal Operation - CC 1020 and CC 2020 Series
Design Features
| 1. |
Measuring
ranges 0...160 mbar to 0...400 bar rel.; 0...0.4 bar to 0...25 bar
abs. |
| 2. |
Piezoresistive
sensor element. |
| 3. |
Diaphragm
seal operation with reduced inner volume. |
| 4. |
Measuring
system vacuum tight, overload protected. |
| 5. |
Stainless
steel housing as standard or field housing. |
| 6. |
Power supply:
24 V DC, 2 and 3-wire circuitry. |
| 7. |
Explosion
proof, EEx ia/ib. |
| 8. |
EMC test per
valid EU guidelines. |
Data
Sheet
|
 |
Labom
Pressure Transmitter - Measuring Principle Piezoresistive - with Flush Mounted
Diaphragm - CE Series
Design Features
| 1. |
Measuring
ranges 0...2.5 bar to 0...25 bar, rel. and absolute pressure. |
| 2. |
Piezoresistive
sensor element. |
| 3. |
Measuring
system vacuum tight, overload protected. |
| 4. |
Stainless
steel housing as standard or field housing. |
| 5. |
Power supply:
24 V DC, 2- and 3-wire circuitry. |
| 6. |
Explosion
proof EEx ia/ib. |
| 7. |
Electromagnetic
Compatibility (EMC) Test per IEC 801. |
Data
Sheet
|
 |
Labom
Pressure Transmitter with Bourdon Tube System - CK4 Series
Design Features
| 1. |
Measurement
ranges 0...0.6 bar to 0...1000 bar. |
| 2. |
Stainless
steel case and measuring system. |
| 3. |
Solid front
case. |
| 4. |
Signal output:
Load-independent DC signal 0(4)...20mA. |
| 5. |
Connection
with 2,3 or 4-wire circuitry. |
| 6. |
Built-in power
supply with electrical isolation (optional). |
| 7. |
Explosion
proof, EEx ib IIC T6. |
|
|
Labom
Pressure Transmitter with Diaphragm Measuring Element - CK2000 - Series
Design Features
| 1. |
Measuring
ranges 0...25 mbar to 0...25 bar. |
| 2. |
Stainless
steel or Duratherm case and measuring system. |
| 3. |
Solid front
case with high excess pressure protection. |
| 4. |
Signal output:
Load-independent DC signal 0(4) ...20mA. |
| 5. |
Connection
with 2-, 3- or 4-wire circuitry. |
| 6. |
Built-in power
supply with electrical isolation (optional). |
| 7. |
Explosion
proof, EEx ib IIC T6 (optional). |
| 8. |
EMC test per
valid EC guidelines. |
|